What is a SAP calculation?
A SAP (Standard Assessment Procedure) calculation is the UK government's approved methodology for assessing the energy performance of a residential dwelling. It produces a score between 1 and 100+ that reflects the predicted energy cost of running the home — covering space heating, hot water, ventilation and fixed lighting.
Under Part L of the Building Regulations, every new residential build requires an approved SAP calculation before construction begins (the Design Stage) and again at completion (the As-Built Stage).
What's changed under Part L 2021
The 2021 update to Part L introduced a number of significant changes:
- A tightening of the Fabric Energy Efficiency Standard (FEES) to 40 kWh/m²/yr for houses and 29 kWh/m²/yr for flats.
- The introduction of the Primary Energy metric alongside CO₂ as a compliance target.
- A minimum requirement for low-carbon heating in many new builds.
- Improved air-tightness targets, with mandatory testing on most plots.
What you'll need to provide
To produce an accurate SAP calculation we'll need:
- Architectural drawings (plans, elevations, sections).
- Construction build-up details and proposed U-values.
- Window and door schedules.
- Heating, hot water and ventilation specifications.
- Any renewable or low-carbon technologies.
How to pass first time
The most common reasons for failure are under-specified insulation, oversized glazing on north-facing elevations, and missing low-carbon heating. Engaging an accredited assessor early — ideally at RIBA Stage 3 — gives you the best chance of a clean pass.
Need a quote?
Get in touch for a free, no-obligation quote. Most straightforward plots are turned around within 2–3 working days.